G. Gori et al., HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHYL ETHYLKETONE IN URINE AS ITS 3-METHYL-2-BENZOTHIAZOLINONE HYDRAZONE DERIVATIVE, Chromatographia, 40(5-6), 1995, pp. 336-340
A HPLC method for the determination of methyl ethyl ketone (MEK) in ur
ine after derivatization with 3-methyl-2-benzothiazolinone hydrazone i
s proposed. The calibration curve for the ketone was linear, ranging b
etween 0.23-10 mg/L, with a detection limit of 0.025 mg/L. The results
were compared to those obtained by GC-MS, coupled to the headspace te
chnique. MEK derivatization and the derivative purification processes
were verified with respect to the main variables such as reaction temp
erature, reagent concentration, probable interferences and enrichment
phase. The method is simple and reliable and shows a good sensitivity.