Ll. Razumova et al., THE STABILITY OF SEGMENTED POLYURETHANES - STRUCTURE DEVELOPMENT ON CONTACT WITH BLOOD, International journal of polymeric materials, 27(1-2), 1994, pp. 15-19
The segmented polyurethanes (SPU) of Vitur-RM trademark are widely use
d thrombosis resistant SPUs. The changes in the structure of their col
loid level sizes and in stability characteristics were studied after i
ncubation of SPU films in blood serum for a period of 1-2 years at 40
degrees C. The small-angle X-ray scattering using linear coordination
detector showed that the domain sizes did not change noticeably on inc
ubations. The strength characteristics decreased by not more than by 1
0-15% during this of exposure. The characteristics investigated differ
ed markedly from those found with samples with initially low strength,
corresponding to the lowest limit of the Russian standard.