STATIONARY ELECTROPHORETIC DEPOSIT AS A CONCENTRATED DISPERSE SYSTEM - EFFECT OF ACCUMULATIVE MECHANISM

Citation
Zr. Ulberg et al., STATIONARY ELECTROPHORETIC DEPOSIT AS A CONCENTRATED DISPERSE SYSTEM - EFFECT OF ACCUMULATIVE MECHANISM, Progress in organic coatings, 25(3), 1995, pp. 283-292
Citations number
3
Categorie Soggetti
Chemistry Applied","Materials Science, Coatings & Films
ISSN journal
03009440
Volume
25
Issue
3
Year of publication
1995
Pages
283 - 292
Database
ISI
SICI code
0300-9440(1995)25:3<283:SEDAAC>2.0.ZU;2-I
Abstract
The present paper deals with the numerical solution of the problem spe cified in Ref. [1], which consists of the determination of the station ary distribution of disperse particle concentration and pressure with regard to the hydrodynamic and electrical interaction between the part icles in the electrophoretic deposit. On the basis of this numerical s olution a procedure was proposed allowing for the determination of an approximated analytical expression for the above-mentioned distributio ns as well as for calculating the position of the boundary between the stable and coagulated portions of a deposit. The condition when the v ariation in electrolyte concentration caused by the electric current i s not essential (the concentration polarization) and deposition occurs owing to the effect of the accumulative (Hamaker) mechanism and not o f the electrochemical one were also studied.