SELECTIVE COMPLEXOMETRIC DETERMINATION OF MERCURY USING ACETYLACETONEAS MASKING AGENT

Citation
B. Mathew et al., SELECTIVE COMPLEXOMETRIC DETERMINATION OF MERCURY USING ACETYLACETONEAS MASKING AGENT, Analyst, 120(4), 1995, pp. 1097-1098
Citations number
17
Categorie Soggetti
Chemistry Analytical
Journal title
ISSN journal
00032654
Volume
120
Issue
4
Year of publication
1995
Pages
1097 - 1098
Database
ISI
SICI code
0003-2654(1995)120:4<1097:SCDOMU>2.0.ZU;2-O
Abstract
A complexo-titrimetric method for the determination of mercury(II) in the presence of other metal ions is described, based on the selective masking ability of acetylacetone. Mercury and other ions in a given sa mple solution are initially complexed with excess of EDTA and the surp lus EDTA is titrated with lead nitrate solution at pH 5.0-6.0 (adjuste d with hexamine) using Xylenol Orange as indicator. An excess of a 10% alcoholic solution of acetylacetone is then added to decompose the Hg -II-EDTA complex and the EDTA released is titrated with lead nitrate s olution. Reproducible and accurate results are obtained for 3-55 mg of mercury with relative errors of <0.3% and standard de deviations of < 0.04 mg. The lack of effect of foreign ions on the accuracy and precis ion of the method reveals that the method may be suitable for the dete rmination of mercury in its alloys. The method was successfully applie d for the determination of mercury in complexes and synthetic alloy so lutions.