The use of a balloon catheter to distend the rectum for pelvic CT in p
atients with rectal cancer is described. The 20-cm long balloon, inser
ted over a 12F catheter and inflated with 180-200 ml of water is simpl
e to use, well tolerated by patients and allows high-quality CT scans.
Preliminary results of the presurgical staging of rectal cancer by CT
with rectal balloon in a series of 15 patients show a high accuracy w
hen compared with the pathological findings: involvement of perirectal
nodes and adjacent structures was correctly identified in all cases,
while CT overestimated the invasion of perirectal fat in two cases, du
e to the impossibility of distinguishing neoplastic from inflammatory
tissue. The operability statement (site and dimensions of the tumour)
allowed correct surgical planning in all cases.