Gb. Duncan et al., A MODEL OF A FIXED-FILM TRICKLE-FILTER BIOREACTOR FOR TCE DEGRADATION, Separation science and technology, 30(7-9), 1995, pp. 1791-1805
A mechanistically based model of a fixed-film trickle-filter bioreacto
r for cometabolic degradation of TCE has been developed. This model in
corporates diffusional and kinetic resistances and generates estimates
of TCE stripped from the liquid by gas as well as the extent of biolo
gical degradation of TCE. The model is consistent with a limited amoun
t of experimental data. Further experience with this modeling approach
is necessary in order to determine if this is a useful procedure for
correlating ioreactor performance for design and scale-up.