Organic fluids are widely used in our personal world and in technology
. Since most of them are hazardous when they join the groundwater, con
crete structures are built for environmental protection. Due to its po
rosity, concrete is not a priori impervious, and it has to be tested t
o determine the requirements to be met for technical applications. Tes
ts are presented for measuring capillary absorption and diffusion coef
ficients continuously. Five concrete mixes were examined with acetone
as test fluid, and the results are discussed.