3-BODY WEAR OF LIGHT-ACTIVATED COMPOSITE VENEERING MATERIALS

Citation
H. Matsumura et al., 3-BODY WEAR OF LIGHT-ACTIVATED COMPOSITE VENEERING MATERIALS, The Journal of prosthetic dentistry, 73(3), 1995, pp. 233-239
Citations number
11
Categorie Soggetti
Dentistry,Oral Surgery & Medicine
ISSN journal
00223913
Volume
73
Issue
3
Year of publication
1995
Pages
233 - 239
Database
ISI
SICI code
0022-3913(1995)73:3<233:3WOLCV>2.0.ZU;2-J
Abstract
The in vitro wear of two types of composite resin veneering materials was determined by use of a three-body wear testing device. The wear of a microfilled high-filler content composite resin (Dentacolor) was le ss than that of a hybrid low-filler content one (Visio-Gem). The worn surface of Dentacolor material was smoother than that of Visio-Gem mat erial. The wear-testing results and scanning electron micrographs demo nstrated that the findings obtained by this wear-testing device correl ated well with clinical findings.