K. Mishima et al., CORRELATION OF BIOCONCENTRATION FACTOR WI TH PARTITION-COEFFICIENT OFBENZENE-DERIVATIVES IN AQUEOUS 2-PHASE SYSTEM, Kagaku kogaku ronbunshu, 21(1), 1995, pp. 234-236
The partition coefficients of eight kinds of benzene derivatives, whic
h are well-known toxic compounds, were measured in the aqueous two-pha
se systems containing polyethylene glycol(($) over bar M(W)=7,500) and
dipotassium hydrogenphosphate at 298.15 K. Results of correlation of
bioconcentration factors with the partition coefficients measured in t
he aqueous two-phase system were compared with these obtained from the
literature data which were determined in the octanol-water partition
system for the benzene derivatives. It was found that the partition co
efficients of benzene derivatives measured in the aqueous two-phase sy
stem could give a better correlation with the bioconcentration factors
.