The model stresses the role played by the distribution of the current
lines around the blockers and by the dielectric properties of these bl
ockers. When the matrix conductivity is low enough, isolated spaces ap
pear on both sides of the blockers. This model is consistent with most
of the experimental features of ion-blocking in conducting ceramics,
including the decrease of the blocking factor with temperature and the
similarity between the bulk and blocked conductance activation energi
es. The admittance diagram parameters can be correlated to the geometr
ical parameters of the blockers. Additional relevant results obtained
with alumina-zirconia composites reveal the limits of the model.