MICRON SPATIAL-RESOLUTION X-RAY IMAGE PLATES WITH NON-ERASING READING

Citation
Ip. Dolbnya et al., MICRON SPATIAL-RESOLUTION X-RAY IMAGE PLATES WITH NON-ERASING READING, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 359(1-2), 1995, pp. 376-378
Citations number
4
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
359
Issue
1-2
Year of publication
1995
Pages
376 - 378
Database
ISI
SICI code
0168-9002(1995)359:1-2<376:MSXIPW>2.0.ZU;2-H
Abstract
New silverless radiophotoluminescence substances NaCl(Me) and LiF(Me) are proposed and tested as X-ray image detectors. Their spatial resolu tion is not worse than 2 mu m and they allow one to register X-ray pic tures with a dynamic range of about 5000. A stored X-ray image can be read out many times by photoluminescence measurements under UV excitat ion. The image can be erased completely by heating the substances up t o a temperature of 400 degrees C during 0.5 h.