W. Estelberger et al., DETERMINATION OF THE GLOMERULAR-FILTRATION RATE BY IDENTIFICATION OF SINISTRIN KINETICS, European journal of clinical chemistry and clinical biochemistry, 33(4), 1995, pp. 201-209
A computer-based method of system identification and estimation of par
ameter variance for two-compartment models matched to dynamic sinistri
n concentration profiles for the determination of glomerular filtratio
n rate is described. Thereby a procedure for the judgment of the optim
al sampling time horizon is presented. Since single-injection techniqu
es are suspected of yielding systematic overestimation of the glomerul
ar filtration rate, a method is demonstrated confirming that such a te
chnique employing sinistrin kinetics can be used to correctly determin
e the glomerular filtration rate. The validation of the system paramet
ers gained by the single-injection method is made through prediction o
f the concentration contour under a constant infusion regimen in the s
ame subject on a different occasion. This was performed in healthy con
trols and in patients with various degrees of renal insufficiency. Upo
n consideration of the dependence of the clearance estimates and their
variances on the protocol duration in test subjects examined from fou
r to ten hours, an adaptive design of the protocol length is developed
.