A TECHNIQUE FOR THE EXCHANGE OF TUNNELED POLYMERIC SILICONE CATHETERSAND IMPLANTABLE INFUSION PORTS

Citation
Ja. Lowell et al., A TECHNIQUE FOR THE EXCHANGE OF TUNNELED POLYMERIC SILICONE CATHETERSAND IMPLANTABLE INFUSION PORTS, The American journal of surgery, 169(6), 1995, pp. 631-633
Citations number
19
Categorie Soggetti
Surgery
ISSN journal
00029610
Volume
169
Issue
6
Year of publication
1995
Pages
631 - 633
Database
ISI
SICI code
0002-9610(1995)169:6<631:ATFTEO>2.0.ZU;2-S
Abstract
Tunneled polymeric silicone catheters and implantable infusion ports a re used with increasing frequency. Complications may occur with cathet er placement or ongoing use. A new technique is described that minimiz es the risks associated with catheter reinsertion in patients with tun neled polymeric silicone catheters that are either malfunctioning or m ispositioned. This procedure allows for the exchange of these catheter s without incurring the risk of a new venipuncture.