Cj. Tsai et Hy. Huang, ATMOSPHERIC AEROSOL SAMPLING BY AN ANNULAR DENUDER SYSTEM AND A HIGH-VOLUME PM(10) SAMPLER, Environment international, 21(3), 1995, pp. 283-291
An Annular Denuder System (ADS) was used to study sampling errors of t
otal PM(10) and soluble ionic species concentrations determined by the
high volume PM(10) (HVPM(10)) sampler. Experimental results show that
in the HVPM(10) sampler, more alkaline glass fiber filters collect mo
re sulfate and nitrate but less ammonium ion than quartz filters. Howe
ver, total PM(10) concentrations do not seem to depend on the types of
filters. Artifact sulfate concentrations in glass fiber filters of th
e HVPM(10) sampler are found to exceed those predicted by the Coutant'
s model. It is suggested that artifact sulfate and nitrate not only oc
cur within filters but also in particle deposits. Chloride ion concent
rations in the filters of the HVPM(10) sampler are underestimated sign
ificantly due to evaporative loss of ammonium chloride.