INFLUENCING FACTORS ON ESR BONE DOSIMETRY

Citation
S. Onori et al., INFLUENCING FACTORS ON ESR BONE DOSIMETRY, Applied radiation and isotopes, 47(11-12), 1996, pp. 1637-1640
Citations number
17
Categorie Soggetti
Nuclear Sciences & Tecnology","Radiology,Nuclear Medicine & Medical Imaging","Chemistry Inorganic & Nuclear
Journal title
Applied radiation and isotopes
ISSN journal
09698043 → ACNP
Volume
47
Issue
11-12
Year of publication
1996
Pages
1637 - 1640
Database
ISI
SICI code
0969-8043(1996)47:11-12<1637:IFOEBD>2.0.ZU;2-K
Abstract
This paper reports on the influence that temperature during irradiatio n and dose-rate have on the radiation-induced free-radical yield and t ime stability in non de-proteinized bone. Bone from chicken legs was i rradiated in the 253-293 K temperature range and with two different so urces (Co-60, 0.6 Gy/s and 12 MeV electrons, 6 x 10(6) Gy/s). Temperat ure influences type and number of radicals, while radical concentratio n seems to slightly decrease with dose rate. Copyright (C) 1996 Elsevi er Science Ltd