ELECTRONICS FOR VERY HIGH-RATE TRACKING DETECTORS

Citation
Hh. Williams et al., ELECTRONICS FOR VERY HIGH-RATE TRACKING DETECTORS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 360(1-2), 1995, pp. 146-149
Citations number
8
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
360
Issue
1-2
Year of publication
1995
Pages
146 - 149
Database
ISI
SICI code
0168-9002(1995)360:1-2<146:EFVHTD>2.0.ZU;2-S
Abstract
Results are presented on a system of electronics designed for very hig h rate tracking detectors at the SSC and LHC. The primary goal was a s ystem for signal detection, time measurement, and readout for the stra w tracker for SDC. An integrated circuit incorporating eight channels of amplifier-shaper-discriminator (including detector tail cancellatio n), and two different integrated circuits for time measurement are des cribed. The performance of tracking measurements up to counting rates of 8 MHz per wire is reported, as well as preliminary results from a b aseline restoration circuit.