INCIDENT ANGLE EFFECT ON THE QUANTUM EFFICIENCY OF CSI PHOTOCATHODES

Citation
P. Mine et al., INCIDENT ANGLE EFFECT ON THE QUANTUM EFFICIENCY OF CSI PHOTOCATHODES, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 360(1-2), 1995, pp. 430-431
Citations number
6
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
360
Issue
1-2
Year of publication
1995
Pages
430 - 431
Database
ISI
SICI code
0168-9002(1995)360:1-2<430:IAEOTQ>2.0.ZU;2-2
Abstract
A systematic investigation of the effect of incident angle of the inco ming UV light on the quantum efficiency of CsI photocathodes in the sp ectral range 140-220 nm is presented. The measurements were made in va cuum. A decrease of the photocurrent with an increase of the photon an gle of incidence is observed, reaching a relative loss of 30% for an i ncidence angle of 55 degrees at a wavelength of 210 nm.