DETERMINATION OF ACEFYLLINE HEPTAMINOL IN PHARMACEUTICAL PREPARATIONSBY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

Citation
S. Rabouanguyon et al., DETERMINATION OF ACEFYLLINE HEPTAMINOL IN PHARMACEUTICAL PREPARATIONSBY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, Il Farmaco, 51(11), 1996, pp. 739-746
Citations number
7
Categorie Soggetti
Pharmacology & Pharmacy
Journal title
ISSN journal
0014827X
Volume
51
Issue
11
Year of publication
1996
Pages
739 - 746
Database
ISI
SICI code
0014-827X(1996)51:11<739:DOAHIP>2.0.ZU;2-O
Abstract
This paper describes two simple and rapid procedures for the determina tion of heptaminol and of both acetylline and benzyl alcohol, using re versed phase high performance liquid chromatography under isocratic co nditions and UV spectrophotometric detection. For heptaminol, procedur e includes a precolumn derivatizatin by orthophthaldialdehyde in prese nce of reducing agent, in alkaline buffer. It is specific, linear, acc urate (recovery mean = 99.90 +/- 0.44%), reliable (precision = 1.00%) and sensitive (0.007 mg/l in the drug). For acefylline and benzyl alco hol, the procedure uses hexadecyltrimethylammonium bromide, for an ion -pair technique. It is specific, linear, accurate (recovery means = 99 .65 +/- 0.52% and 99.65 +/- 1.10% respectively), reliable (precisions < 1.5%) and sensitive (0.30 mg/l and 0.01 mu l/l respectively, in the drug).