Jc. Nunes et Aj. Waker, MULTISPHERE SPECTROMETRY AND ANALYSIS OF TEPC AND REM METER RESULTS AROUND A HEAVY-WATER MODERATED REACTOR, Radiation protection dosimetry, 59(4), 1995, pp. 279-284
Citations number
NO
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging","Nuclear Sciences & Tecnology
The NRU reactor is a vertically oriented, heavy water moderated and co
oled research reactor. Water and iron shielding above the core permit
only a small amount of leakage neutrons through the top deck plate. Tw
o leakage neutron spectra determined using a multisphere, or Bonner sp
here, system are reported here. The spectra are used to analyse measur
ements made with a moderator-type neutron dose equivalent meter (i.e.
a rem meter) and a tissue-equivalent proportional counter (TEPC) syste
m. Rem meter readings are not reproduced by folding the response funct
ion of the instrument with the fluence spectra. Based on TEPC and Bonn
er sphere data, ambient dose equivalents are found to be 30 and 17 mu
Sv.h(-1) (+/-25%), in the two locations investigated, for a reactor po
wer level of 107 MW(t).