RADON TRANSPORT IN A DRILLED WELL STUDIED BY ETCHED TRACK TYPE RADON MONITORS

Citation
I. Csige et al., RADON TRANSPORT IN A DRILLED WELL STUDIED BY ETCHED TRACK TYPE RADON MONITORS, Radiation measurements, 25(1-4), 1995, pp. 561-564
Citations number
3
Categorie Soggetti
Nuclear Sciences & Tecnology
Journal title
ISSN journal
13504487
Volume
25
Issue
1-4
Year of publication
1995
Pages
561 - 564
Database
ISI
SICI code
1350-4487(1995)25:1-4<561:RTIADW>2.0.ZU;2-D
Abstract
We have measured the radon concentration profile along a 20 meter deep drilled well with etched track type radon monitors. The well has a di ameter of 12. cm. It has water at 11.6 meter below the surface and exh ales nearly 100% carbon dioxide of geological origin at rate of about 300 liters/hour. We made radon measurements both underwater and in the gaseous atmosphere. Radon transport models (such as microbubble, macr obubble, eddy diffusion, etc.) were tested to find the best fit to exp erimental radon profiles. The measuring site is at a geologically acti ve area, and the effect of a small earthquake on the exhalation rate o f CO2 from the well was also observed.