DETERMINATION OF RADON AND RADIUM CONTENT OF WATER SAMPLES BY SSNTD TECHNIQUE

Citation
J. Hakl et al., DETERMINATION OF RADON AND RADIUM CONTENT OF WATER SAMPLES BY SSNTD TECHNIQUE, Radiation measurements, 25(1-4), 1995, pp. 657-658
Citations number
2
Categorie Soggetti
Nuclear Sciences & Tecnology
Journal title
ISSN journal
13504487
Volume
25
Issue
1-4
Year of publication
1995
Pages
657 - 658
Database
ISI
SICI code
1350-4487(1995)25:1-4<657:DORARC>2.0.ZU;2-1
Abstract
We have developed a method to determine the dissolved radon and radium content of water samples using etch track type radon monitors. In two measurements the radon exposures in a freshly sealed and in a degasse d water sample are determined. From the measured exposures the radon a nd radium content of water is calculated.