DIFFRACTION AND DIFFUSE-SCATTERING FROM MATERIALS WITH MICROFOCUSED X-RAYS

Citation
C. Riekel et P. Engstrom, DIFFRACTION AND DIFFUSE-SCATTERING FROM MATERIALS WITH MICROFOCUSED X-RAYS, Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 97(1-4), 1995, pp. 224-230
Citations number
19
Categorie Soggetti
Physics, Nuclear","Nuclear Sciences & Tecnology","Instument & Instrumentation
ISSN journal
0168583X
Volume
97
Issue
1-4
Year of publication
1995
Pages
224 - 230
Database
ISI
SICI code
0168-583X(1995)97:1-4<224:DADFMW>2.0.ZU;2-I
Abstract
Status and development possibilities of microfocusing experiments in w ide- and small angle scattering at the ESRF microfocus beamline are re ported. The routinely available beam sizes range from approximate to 2 00 pm to 7 mu m using mirror/monochromator optics. For the smallest be am size post collimation is required. Optics based on glass capillary and Bragg-Fresnel elements have been tested for mu m or sub mu m appli cations.