MODELING AND STABILITY OF HYDRO PLANT WITH 2 SURGE TANKS

Citation
Cd. Vournas et G. Papaioannou, MODELING AND STABILITY OF HYDRO PLANT WITH 2 SURGE TANKS, IEEE transactions on energy conversion, 10(2), 1995, pp. 368-375
Citations number
10
Categorie Soggetti
Engineering, Eletrical & Electronic","Energy & Fuels
ISSN journal
08858969
Volume
10
Issue
2
Year of publication
1995
Pages
368 - 375
Database
ISI
SICI code
0885-8969(1995)10:2<368:MASOHP>2.0.ZU;2-Z
Abstract
This paper deals with the modelling and the stability analysis of a hy droelectric power plant with two surge tanks placed upstream and downs tream of the turbine. The interaction of the two surge tanks is invest igated and the system is simulated for the case of sudden opening or c losure of the turbine gates. The stability of the frequency control lo op is assessed by using small signal analysis based on linearization. The above procedures have been applied to a real situation and proved to be extremely useful for preliminary design purposes.