FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF FREE RESIDUAL CHLORINE IN WATERS WITH 3,3'-DIMETHYLNAPHTIDINE

Citation
E. Pobozy et al., FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF FREE RESIDUAL CHLORINE IN WATERS WITH 3,3'-DIMETHYLNAPHTIDINE, Microchemical journal, 51(3), 1995, pp. 379-386
Citations number
18
Categorie Soggetti
Chemistry Analytical
Journal title
ISSN journal
0026265X
Volume
51
Issue
3
Year of publication
1995
Pages
379 - 386
Database
ISI
SICI code
0026-265X(1995)51:3<379:FSDOFR>2.0.ZU;2-8
Abstract
Application of 3,3-dimethylnaphtidine as chromogenic reagent in the fl ow-injection system with spectrophotometric detection enables the dete rmination of free residual chlorine with sufficient selectivity and de tectability with sampling rate 150 samples per hour. The developed met hod was satisfactorily applied to the analysis of treated water sample s, although their limited selectivity to chloramines was also demonstr ated. (C) 1995 Academic Press, Inc.