N. Kikuiri et al., A MASK-TO-WAFER FINE GAP SETTING METHOD, International journal of the Japan Society for Precision Engineering, 29(1), 1995, pp. 56-61
This paper describes a mask-to wafer gap setting method for an X-ray s
tepper. A capacitance micrometer on the wafer chuck and those on the m
ask chuck are used in this method. The mask and wafer surfaces are pos
itioned parallel to the travel plane of the wafer x-y stage so that th
e gap does not vary with the step and repeat motion of the wafer stage
. Therefore, gap setting is required only once for each wafer, and the
throughput becomes better. This method has the following two addition
al merits. A complex gap measurement optics is not required and the se
tting value of the gap is variable. The gap setting error caused by ma
sk unflatness, wafer unflatness and travel error of the wafer x-y stag
e was analyzed. Experiments were carried out using mask and wafer stag
es both with six axes. A gap setting accuracy better than +/- 1.5 mu m
at the exposure positions of 5 wafers has been achieved for 30 mu m a
nd 20 mu m gaps.