This paper presents an analysis of the effects of motor repair of moto
r efficiency. The study is based on laboratory testing of 23 50-hp mot
ors sent to 23 motor repair shops. The results show that the drop in e
fficiency is directly related to work practices, mainly due to the sta
tor characteristics and poor bearing lubrication. The stator Stripping
methods used have little impact on core losses.