A bench-scale system was constructed at the Energy and Environmental R
esearch Center (EERC) to screen performance of various types of V/Ti c
atalyst-coated, high-temperature, fabric filters manufactured at Owens
-Corning, Inc.(OCF). This product is targeted for use in utility and i
ndustrial facilities for simultaneous NOx and particulate control. Des
cribed in this paper are the bench-scale system design, operation, and
validation of the data produced.