XUV OPACITY MEASUREMENTS AND COMPARISON WITH MODELS

Citation
G. Winhart et al., XUV OPACITY MEASUREMENTS AND COMPARISON WITH MODELS, Journal of quantitative spectroscopy & radiative transfer, 54(1-2), 1995, pp. 437-446
Citations number
20
Categorie Soggetti
Spectroscopy
ISSN journal
00224073
Volume
54
Issue
1-2
Year of publication
1995
Pages
437 - 446
Database
ISI
SICI code
0022-4073(1995)54:1-2<437:XOMACW>2.0.ZU;2-Z
Abstract
The opacities of aluminium, iron and holmium were measured spectrally resolved in the energy range of 70 to 280 eV. For this purpose the iod ine laser ASTERIX IV at the MPQ (200J/0.4 ns at 440 nm) was focused in to a spherical gold Hohlraum with a dia of 3 mm. The generated radiati on with a temperature of 60 eV heated thin tampered absorber foils. Th e transmission was measured spectrally and temporally resolved by mean s of a backlighter source with a delay of 0.8 ns to the main beam, At this delay time the density in the sample material is about 0.01 g/cm( 3) and the temperature is about 20 eV. We have compared the experiment al data with the opacity codes IMP, JIMENA, OPAL, SAPHIR and STA.