OFF-AXIS ALIGNMENT OF AN LDA-PROBE AND THE EFFECT OF ASTIGMATISM ON MEASUREMENTS

Authors
Citation
Z. Zhang et K. Eisele, OFF-AXIS ALIGNMENT OF AN LDA-PROBE AND THE EFFECT OF ASTIGMATISM ON MEASUREMENTS, Experiments in fluids, 19(2), 1995, pp. 89-94
Citations number
11
Categorie Soggetti
Mechanics,"Engineering, Mechanical
Journal title
ISSN journal
07234864
Volume
19
Issue
2
Year of publication
1995
Pages
89 - 94
Database
ISI
SICI code
0723-4864(1995)19:2<89:OAOALA>2.0.ZU;2-R
Abstract
A theoretical analysis of the positional accuracy of an LDA measuremen t volume using an off-axis alignment of a probe relative to an interna l flow has been carried out. General performance parameters of measure ments with a 1D-probe with an off-axis alignment are derived. In parti cular, the change in the fringe spacing, the relationship between the shift of the measurement volume and the probe movement, and the genera l 2-dimensional traversing properties of the measurement volume are co nsidered. The displacement between the two LDA measurement volumes of a 2D-probe caused by astigmatism has been determined from exact calcul ations of the laser beam transmission. The benefits of a water-filled prism to ensure the coincidence of the measurement volumes and to redu ce the effect of astigmatism on the data rate and the distortion of th e measurement volume has been shown. A calculation procedure for the u se of such a prism is given.