MEASUREMENTS OF THE PERFORMANCE OF AN ACOUSTICAL CALIBRATION DUCT

Authors
Citation
Sa. Watkins, MEASUREMENTS OF THE PERFORMANCE OF AN ACOUSTICAL CALIBRATION DUCT, Applied Acoustics, 45(4), 1995, pp. 377-384
Citations number
NO
Categorie Soggetti
Acoustics
Journal title
ISSN journal
0003682X
Volume
45
Issue
4
Year of publication
1995
Pages
377 - 384
Database
ISI
SICI code
0003-682X(1995)45:4<377:MOTPOA>2.0.ZU;2-5
Abstract
This note details an investigation of the performance of an acoustical duct used for the calibration of devices such as microphones, sound l evel meters and sound intensity probes at frequencies less than 250 Hz . The accuracy of the plane wave field produced in the duct was examin ed by measuring the standing wave ratio in the duct and the sound pres sure level variation across a cross-section of the duct. The results s uggest that the duct should only be used to compare pressure responses of acoustical measuring devices of similar physical dimensions.