H. Abe et al., DEVELOPMENT OF DIGITAL POWER RANGE NEUTRO N MONITOR FOR BWR NUCLEAR-POWER-PLANTS, Nippon Genshiryoku Gakkaishi, 37(7), 1995, pp. 628-638
A Digital Power Range Neutron Monitor (DPRNM) has been developed for B
oiling Water Reactor (BWR) nuclear power plants, using digital signal
processing techniques. The DPRNM system has the finite impulse respons
e digital filter which has a band pass characteristics of DC to 10Hz t
o pass neutron detector signals, in which 50Hz or 60Hz signals are sha
rply cut off to attenuate noises coming from the power supply more tha
n 40dB. For fast signal processing, the digital signal processor was u
tilized in the digital filter. In performance tests, frequency charact
eristics, delay time of the digital filter and the response of the DPR
NM for in-core neutron detector signals recorded in a real plant were
measured. It is confirmed that the DPRNM meets the requirements for th
e application to BWR nuclear power plants.