COMBINED PIEZOELECTRIC-HYDRAULIC ACTUATOR BASED ACTIVE VIBRATION CONTROL FOR ROTORDYNAMIC SYSTEM

Citation
P. Tang et al., COMBINED PIEZOELECTRIC-HYDRAULIC ACTUATOR BASED ACTIVE VIBRATION CONTROL FOR ROTORDYNAMIC SYSTEM, Journal of vibration and acoustics, 117(3), 1995, pp. 285-293
Citations number
NO
Categorie Soggetti
Engineering, Mechanical",Acoustics
ISSN journal
10489002
Volume
117
Issue
3
Year of publication
1995
Pages
285 - 293
Database
ISI
SICI code
1048-9002(1995)117:3<285:CPABAV>2.0.ZU;2-3
Abstract
Previous research by the authors concentrated on using piezoelectric a ctuators for active vibration control (AVC) of rotating machinery. The current work extends this by positioning the piezo-actuator remotely from the controlled structure and transmitting the control force via a hydraulic line and two pistons. Liquid plastic (LP) is employed as tr ansmission ''fluid'' to obtain a high bulk modulus and low leakage. Th e paper presents results for bulk moduli measurement, and bench and ri g tests for the entire actuator system. These results show the high ef fectiveness of the hybrid actuator for controlling vibrations on a lab oratory rotor test rig.