Y. Mechref et Z. Elrassi, CAPILLARY ELECTROPHORESIS OF HERBICIDES .2. EVALUATION OF ALKYLGLUCOSIDE CHIRAL SURFACTANTS IN THE ENANTIOMERIC SEPARATION OF PHENOXY ACID HERBICIDES, Journal of chromatography, 757(1-2), 1997, pp. 263-273
Citations number
38
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Two chiral alkylglucoside surfactants, namely n-octyl-(OG) and n-nonyl
-beta-D-glucopyranoside (NG), were evaluated in the enantiomeric separ
ation of phenoxy acid herbicides. The enantiomeric resolution could be
manipulated readily by adjusting the surfactant concentration, ionic
strength, pH and separation temperature. The optimum surfactant concen
tration needed for maximum enantiomeric resolution varied among the di
fferent analytes and was an inverse function of the hydrophobicity of
the phenoxy acid herbicides, with the most hydrophobic solute requirin
g less surfactant concentration for attaining a baseline enantiomeric
resolution. Due to the ionic nature of the phenoxy acid herbicides, in
creasing the pH of the running electrolytes increased the degree of io
nization of the acidic herbicides thus decreasing their association wi
th the chiral micelles and in turn their enantiomeric resolution. Incr
easing the ionic strength seems to enhance both the solubilization of
the solute in the micelle and the chiral interaction of the solute wit
h the micelle with a net increase in enantiomeric resolution. Performi
ng the separation at a sub-ambient temperature favoured an enhanced so
lute-micelle association and improved enantiomeric resolution.