TESTING OF A SUPERCONDUCTING SPECTROMETER DIPOLE

Citation
Af. Zeller et al., TESTING OF A SUPERCONDUCTING SPECTROMETER DIPOLE, IEEE transactions on applied superconductivity, 5(2), 1995, pp. 654-657
Citations number
4
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
10518223
Volume
5
Issue
2
Year of publication
1995
Part
1
Pages
654 - 657
Database
ISI
SICI code
1051-8223(1995)5:2<654:TOASSD>2.0.ZU;2-I
Abstract
A superconducting dipole magnet for use as spectrometer element has be en constructed and is presently being mapped. The 75 ton dipole has a negative curvature side and a 15 cm gap. The cryostable coil produced a central field of 1.6 T at a current of 436 A. A second identical mag net is presently under construction.