AC BEHAVIOR OF FULL-SIZE, FUSION DEDICATED CABLE-IN-CONDUIT CONDUCTORS IN SULTAN-III UNDER APPLIED PULSED-FIELD

Citation
B. Blau et al., AC BEHAVIOR OF FULL-SIZE, FUSION DEDICATED CABLE-IN-CONDUIT CONDUCTORS IN SULTAN-III UNDER APPLIED PULSED-FIELD, IEEE transactions on applied superconductivity, 5(2), 1995, pp. 697-700
Citations number
7
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
10518223
Volume
5
Issue
2
Year of publication
1995
Part
1
Pages
697 - 700
Database
ISI
SICI code
1051-8223(1995)5:2<697:ABOFFD>2.0.ZU;2-P
Abstract
The coupling current-losses of a full size, fusion dedicated Nb3Sn cab le-in-conduit superconductor are measured as a function of the transve rse load in the SULTAN III test facility. Applying a broad range of tr ansport current (up to 56 kA) and background field (up to 12.1 T), the change of the transverse resistance is observed through the shift of the 0-crossing in the pick-up coil voltage. Despite the difficulty to extract useful information from the signal, the role of the strand Cr plating as resistive barrier is experimentally assessed under operatin g conditions. The friction factor of the conductor is also evaluated f ront pressure drop measurements.