A DIAGNOSTIC METHOD OF ION MINORITY CONCENTRATIONS BASED ON IBW PROPAGATION

Citation
C. Riccardi et al., A DIAGNOSTIC METHOD OF ION MINORITY CONCENTRATIONS BASED ON IBW PROPAGATION, Plasma physics and controlled fusion, 37(8), 1995, pp. 883-889
Citations number
7
Categorie Soggetti
Phsycs, Fluid & Plasmas
ISSN journal
07413335
Volume
37
Issue
8
Year of publication
1995
Pages
883 - 889
Database
ISI
SICI code
0741-3335(1995)37:8<883:ADMOIM>2.0.ZU;2-6
Abstract
A diagnostic method for ion minority concentrations, based on the prop agation of ion Bernstein waves (IBW), is analysed theoretically and ve rified experimentally. The results obtained are compared with those pr ovided by the neutralized ion Bernstein waves (NIBW) based diagnostic, as used in previous experiments.