PERFORMANCE OF THE BGO ENDCAP CALORIMETER WITH PHOTOTRIODE READOUT FOR THE CMD-2 DETECTOR

Citation
Dn. Grigoriev et al., PERFORMANCE OF THE BGO ENDCAP CALORIMETER WITH PHOTOTRIODE READOUT FOR THE CMD-2 DETECTOR, IEEE transactions on nuclear science, 42(4), 1995, pp. 505-509
Citations number
10
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
42
Issue
4
Year of publication
1995
Part
1
Pages
505 - 509
Database
ISI
SICI code
0018-9499(1995)42:4<505:POTBEC>2.0.ZU;2-H
Abstract
The endcap calorimeter of the CMD-2 detector for the VEPP-2M collider is described. The calorimeter contains 680 EGO crystals read out by va cuum phototriodes. Charge sensitive preamplifiers are placed directly on the phototriodes for the best noise performance. The calorimeter wa s installed during the last year. Calibration by cosmic rays showed th e energy equivalent of the electronic noise to be about 0.9 MeV during operation in a 1 T magnetic field which corresponds to the design val ue.