We present the Cherenkov Ring Imaging Detector in the endcap regions o
f the SLD detector and report initial performance. The endcap GRID was
completed and commissioned in 1993 and is fully operational for the 1
994 run. First Cherenkov rings have been observed. The endcap GRID det
ectors and fluid systems are described and initial operational experie
nce is discussed.