W. Friedl et al., IONIC-STRENGTH AND CHARGE NUMBER CORRECTION FOR MOBILITIES OF MULTIVALENT ORGANIC-ANIONS IN CAPILLARY ELECTROPHORESIS, Journal of chromatography, 709(1), 1995, pp. 163-170
Citations number
17
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
An empirical expression was derived for the actual mobility, mu, valid
in an extended range of ionic strength, I, between 0.001 and 0.1 mol/
l, using a three-parameter exponential fit for the ratio of actual and
absolute mobilities (mu(0) at I = 0), which consists of two variables
: ionic strength of the buffer and charge number, z, of the solute. Th
e charge numbers of the solute anions (21 aromatic sulfonates) ranged
between 1 and 6, and the ionic strength was varied in the range mentio
ned using a sodium acetate buffer. The mobilities were determined at 2
5.0 degrees C in a coated capillary with suppressed electroosmotic flo
w. The resulting fitting equation, valid under these conditions, is mu
/mu(0) = exp(-0.77 root zI). The difference between measured mobilitie
s and mobilities calculated from a tenfold higher or lower ionic stren
gth, using this equation, is within 5% for all experiments. For multiv
alent ions, mu values can be derived from mu(0) with comparable accura
cy.