A CONSTANT VOLUME APPARATUS FOR VAPOR-PRESSURE AND GAS-PHASE P-V-T MEASUREMENTS - VALIDATION WITH DATA FOR R22 AND R134A

Citation
G. Giuliani et al., A CONSTANT VOLUME APPARATUS FOR VAPOR-PRESSURE AND GAS-PHASE P-V-T MEASUREMENTS - VALIDATION WITH DATA FOR R22 AND R134A, Fluid phase equilibria, 109(2), 1995, pp. 265-279
Citations number
12
Categorie Soggetti
Engineering, Chemical","Chemistry Physical
Journal title
ISSN journal
03783812
Volume
109
Issue
2
Year of publication
1995
Pages
265 - 279
Database
ISI
SICI code
0378-3812(1995)109:2<265:ACVAFV>2.0.ZU;2-1
Abstract
We describe a constant volume apparatus using a spherical cell for the experimental determination of vapour pressure and gas phase pressure- volume-temperature (P-v-T) data for alternative refrigerants. This app aratus has been designed for measurements in the temperature range fro m 245 K to 365 K and for pressures up to 5 MPa. The modifications done to the existing apparatus and the experimental procedure employed to improve the quality of data are explained in detail. The uncertainties involved in the measurement of temperature, pressure, mass and volume are also discussed. New measured data for vapour pressure and P-v-T b ehaviour in gaseous state for high purity samples of chlorodifluoromet hane (R22) and 1,1,1,2-tetrafluoroethane (R134a) and the validation of the experimental procedure are presented. The validation has been per formed by comparing the measured data with correlations and data avail able in recent literature in terms of the following statistical parame ters: percentage deviation, absolute average deviation, bias, standard deviation, root mean square deviation and the difference in pressure. The results indicate that the constant volume cell with measuring ins truments and the procedure employed gives reliable and accurate data.