MEASURED AND EXPECTED COLE PARAMETERS FROM ELECTRICAL-IMPEDANCE TOMOGRAPHIC SPECTROSCOPY IMAGES OF THE HUMAN THORAX

Citation
Bh. Brown et al., MEASURED AND EXPECTED COLE PARAMETERS FROM ELECTRICAL-IMPEDANCE TOMOGRAPHIC SPECTROSCOPY IMAGES OF THE HUMAN THORAX, Physiological measurement, 16, 1995, pp. 57-67
Citations number
10
Categorie Soggetti
Biophysics,"Engineering, Biomedical",Physiology
Journal title
ISSN journal
09673334
Volume
16
Year of publication
1995
Supplement
3A
Pages
57 - 67
Database
ISI
SICI code
0967-3334(1995)16:<57:MAECPF>2.0.ZU;2-P
Abstract
Electrical impedance tomographic spectroscopy (Errs) images have been recorded from a group of 12 normal subjects using frequencies from 9.6 kHz to 1.2 MHz. The impedance changes with frequency have been modell ed on a pixel by pixel basis to produce parametric images as a means o f characterizing tissue. The modelling was based on the Cole equation. The lungs are seen as areas of high characteristic frequency and low time constants SC and RS. The R/S images are much less uniform over th e region of the lungs. Values characterizing the lung and cardiac regi ons are given. The results appear to be consistent with a model for th e lungs whereby the model parameters can be related to alveolar struct ure and composition.