Ca. Perez et al., 3-DIMENSIONAL TREATMENT PLANNING AND CONFORMAL RADIATION-THERAPY - PRELIMINARY EVALUATION, Radiotherapy and oncology, 36(1), 1995, pp. 32-43
Citations number
56
Categorie Soggetti
Oncology,"Radiology,Nuclear Medicine & Medical Imaging
Preliminary clinical results are presented for 209 patients with cance
r who had treatment planned on our three-dimensional radiation treatme
nt planning (3-D RTP) system and were treated with external beam confo
rmal radiation therapy. Average times (min) for CT volumetric simulati
on were: 74 without or 84 with contrast material; 36 for contouring of
tumor/target volume and 44 for normal anatomy; 78 for treatment plann
ing; 53 for plan evaluation/optimization; and 58 for verification simu
lation. Average time of daily treatment sessions with 3-D conformal th
erapy or standard techniques was comparable for brain, head and neck,
thoracic, and hepatobiliary tumors(11.8-14 min and 11.5-12.1, respecti
vely). For prostate cancer patients treated with 3-D conformal techniq
ue and Cerrobend blocks, mean treatment time was 19 min; with multilea
f collimation it was 14 min and with bilateral are rotation, 9.8 min.
Acute toxicity was comparable to or lower than with standard technique
s. Sophisticated 3-D RTP and conformal irradiation can be performed in
a significant number of patients at a reasonable cost. Further effort
s, including dose-escalation studies, are necessary to develop more ve
rsatile and efficient 3-D RTP systems and to enhance the cost benefit
of this technology in treatment of patients with cancer.