PROSPECTIVE VALIDATION OF HIGH-SHEAR WET GRANULATION PROCESS BY WET GRANULE SIEVING METHOD .1. SELECTION AND CHARACTERIZATION OF SIEVING PARAMETERS FOR WET GRANULES

Citation
H. Emori et al., PROSPECTIVE VALIDATION OF HIGH-SHEAR WET GRANULATION PROCESS BY WET GRANULE SIEVING METHOD .1. SELECTION AND CHARACTERIZATION OF SIEVING PARAMETERS FOR WET GRANULES, Drug development and industrial pharmacy, 23(2), 1997, pp. 193-202
Citations number
23
Categorie Soggetti
Chemistry Medicinal","Pharmacology & Pharmacy
ISSN journal
03639045
Volume
23
Issue
2
Year of publication
1997
Pages
193 - 202
Database
ISI
SICI code
0363-9045(1997)23:2<193:PVOHWG>2.0.ZU;2-V
Abstract
To characterize the progression of high-shear wet granulation for vari ous drugs and formulations based on the particle size distribution of wet granules during granulation, a general sieving method for wet gran ules was investigated Wet granulation was conducted in a 25-liter high -shear mixer using four model drugs with different solubilities and pa rticle sizes (ethenzamide, unmilled and milled acetaminophen, and anti pyrine). Because of its small size and efficient sifting mechanism, a sonic sifter was used to determine the wet granulation particle size d istribution. From the good correlation of particle size distribution b etween wet granules and dry-sized granules, an intensity of 80% of ful l-scale amplitude and a sieving time of 3 min were selected as wet gra nule sieving parameters. This general sieving method showed good measu rement precision as long as the determination was completed within 20 min after sampling. Further, the method was independent of sampling po sition within the mixer chamber.