DETECTION OF BREAK LINES AT THE 80-INCH T EMPER MILL OF SOLLAC-FLORANGE

Citation
P. Adnet et al., DETECTION OF BREAK LINES AT THE 80-INCH T EMPER MILL OF SOLLAC-FLORANGE, Revue de métallurgie, 92(6), 1995, pp. 761-765
Citations number
NO
Categorie Soggetti
Metallurgy & Metallurigical Engineering
Journal title
Revue de métallurgie
ISSN journal
00351563 → ACNP
Volume
92
Issue
6
Year of publication
1995
Pages
761 - 765
Database
ISI
SICI code
Abstract
A measuring system allowing a prevention of the defect ''break lines'' on a stand of a temper mill for cold rolled sheets is presented. The aim is to identify automatically the phenomena occuring before the com ing out of the defect in order to modify the rolling schedule. This al lows to suppress the defect (quality improvement), and to increase the service life of the back-up rolls (reliability and costs).