SHORTCOMINGS OF COLOR DOPPLER SONOGRAPHY IN THE DIAGNOSIS OF TESTICULAR TORSION

Authors
Citation
Td. Allen et Js. Elder, SHORTCOMINGS OF COLOR DOPPLER SONOGRAPHY IN THE DIAGNOSIS OF TESTICULAR TORSION, The Journal of urology, 154(4), 1995, pp. 1508-1510
Citations number
15
Categorie Soggetti
Urology & Nephrology
Journal title
ISSN journal
00225347
Volume
154
Issue
4
Year of publication
1995
Pages
1508 - 1510
Database
ISI
SICI code
0022-5347(1995)154:4<1508:SOCDSI>2.0.ZU;2-G
Abstract
Purpose: We determined the shortcomings of color Doppler sonography fo r the diagnosis of testicular torsion. Materials and Methods: We revie wed 5 cases of testicular torsion in which findings on color Doppler s onography were inconsistent with surgical findings. Results: Color Dop pler sonography showed blood flow in 2 patients who had necrotic teste s at surgery. In 3 other patients blood flow was also normal by color Doppler sonography of whom 2 were treated for epididymitis with subseq uent loss of the testes and 1 underwent salvage by immediate explorati on. Conclusions: Testicular torsion is a clinical diagnosis requiring consideration of many variables, Color Doppler sonography is helpful b ut should not be regarded as the definitive discriminator.