NONDESTRUCTIVE CONCENTRATION MEASUREMENTS OF ERBIUM-DOPED ZBLAN FLUOROZIRCONATE GLASS
Citation
S. Rogard et al., NONDESTRUCTIVE CONCENTRATION MEASUREMENTS OF ERBIUM-DOPED ZBLAN FLUOROZIRCONATE GLASS, Optical materials, 4(5), 1995, pp. 557-563
Categorie Soggetti
Material Science
SICI code
0925-3467(1995)4:5<557:NCMOEZ>2.0.ZU;2-N
Abstract
The non-destructive method proposed for the measurements of neodymium
concentrations in laser materials has been extended to erbium-doped fl
uorozirconate glass. It consists of comparing the intensity of a lumin
escence signal from the rare-earth ions with the intensity of a Raman
line from the host matrix, both measured in a single geometry under a
microscope. The investigations have been performed in the erbium-doped
core glass of ZBLAN preforms and multimode optical fibers (in the con
centration range 0-5000 ppm.w). In standard use, the relative error in
the results can be less than 12%. The method is punctual (a few mu m(
3)), and highly sensitive; therefore it seems to be particularly well
adapted for measurements in preforms and in optical fibers.