THE USE OF TL-201 AND TC-99M SUBTRACTION SCINTIGRAPHY FOR THE LOCALIZATION OF PARATHYROID ADENOMAS

Citation
Aj. Renaut et al., THE USE OF TL-201 AND TC-99M SUBTRACTION SCINTIGRAPHY FOR THE LOCALIZATION OF PARATHYROID ADENOMAS, International surgery, 81(3), 1996, pp. 302-303
Citations number
11
Categorie Soggetti
Surgery
Journal title
ISSN journal
00208868
Volume
81
Issue
3
Year of publication
1996
Pages
302 - 303
Database
ISI
SICI code
0020-8868(1996)81:3<302:TUOTAT>2.0.ZU;2-Y
Abstract
Parathyroid adenomas account for approximately 85% of cases of primary hyperparathyroidism. Several preoperative localisation techniques exi st to aid the surgeon during neck exploration, with varying degrees of success. We report on the results of a modification of the establishe d technique of thallium and technetium subtraction scintigraphy. The o perative findings of 60 patients undergoing neck exploration for parat hyroid adenoma were correlated with preoperative thallium and techneti um subtraction scintigraphy scans. The radio-isotopes were administere d in the reverse order to conventional administration, resulting in en hanced imaging. The adenomatous glands were correctly localised in all cases. The 100% sensitivity of this modified scanning technique suppo rts a strategy of unilateral scan-directed neck exploration.