Jm. Mcbirnie et al., A TECHNIQUE FOR CORRECT PLACEMENT OF THE WILSON-COOK ESOPHAGEAL PROSTHESIS IN MALIGNANT TRACHEO-OESPHAGEAL FISTULA, Scandinavian journal of thoracic and cardiovascular surgery, 29(2), 1995, pp. 79-81
A simple technique is described for accurate placement of the Wilson C
ook prosthesis in the management of malignant tracheo-oesophageal fist
ula. This cuffed tube permits effective occlusion of the fistula while
earlier problems of oesophageal intubation (migration, erosion, etc.)
are avoided.