EXPERIMENTAL-STUDY OF PARTICULATE FOULING IN AN INDUSTRIAL PLATE HEAT-EXCHANGER

Citation
D. Bossan et al., EXPERIMENTAL-STUDY OF PARTICULATE FOULING IN AN INDUSTRIAL PLATE HEAT-EXCHANGER, Journal of enhanced heat transfer, 2(1-2), 1995, pp. 167-175
Citations number
10
Categorie Soggetti
Thermodynamics,"Engineering, Mechanical
ISSN journal
10655131
Volume
2
Issue
1-2
Year of publication
1995
Pages
167 - 175
Database
ISI
SICI code
1065-5131(1995)2:1-2<167:EOPFIA>2.0.ZU;2-A
Abstract
An experimental study on particulate fouling in an industrial plate he at exchanger has been carried out on a specially adapted test facility on a semi-industrial experimental platform at GRETh. The presented re sults show the evidence of an asymptotic fouling resistance behaviour. The particle size distribution measurements carried out during the te sts have allowed to check the limit of a diffusion controlled particle deposition. A first attempt to account for the influence of the flow maldistribution between the heat exchangers channel has been proposed.