The objective of this paper is to evaluate the material properties of
SA106 Gr.C carbon steel pipes and their associated welds manufactured
for main steam line of Yonggwang nuclear generating station units 3 an
d 4. Tensile and fracture toughness tests were performed on specimens
taken from actual pipes and the effect of various parameters such as t
he pipe size, the specimen orientation, the test temperature and the w
elding procedure on the material properties are discussed. Fracture to
ughness test results show significant crack plane orientation and test
temperature dependence. An empirical equation correlating tensile and
fracture toughness data is also proposed.